Croatian(HR)

COVERS

01. COVERS FOR ARRANGED FLOORS
02. LIGHT WATER TIGHT MANHOLE COVERS
03. HAVY WATER TIGHT MANHOLE COVERS
04. PRESSURE COVERS

01. COVERS FOR ARRANGED FLOORS

EKOguard COV 1

POKLOPAC ZA UREĐENE PODOVE
Basic measures
:
  • Available cover dimensions:
    COVER DIMENSIONS
    LIGHT OPENING DIMENSIONS
    A x B (mm)
    COVER OUTER DIMENSIONS
    C x D (mm)
    400 x 400
    560 x 560
    500 x 500
    660 x 660
    600 x 600
    760 x 760
    700 x 700
    860 x 860
    800 x 800
    960 x 960
    900 x 900
    1060 x 1060
    1000 x 1000
    1160 x 1160
  • Available cover loads:
    Available cover loads
    According to DIN EN 124:1994)
    Areas inaccessible to motor vehicles
    A15
    15 kN – 1,5t
    Footways, pedestrian areas
    B125
    125 kN – 12,5t
Application:
  • Used in cases when the cover surface is designed to be equal to the floor area on which the cover is installed (when the floor is covered with tiles, stone, granite, marble, laminate), used to maintain floor architectural esthetics.
  • In situation where there are longer channels that have to be shut, covers are installed in series
Cover and frame design:
  • Cover is lowered and filled with concrete filling with appropriate reinforcement. On the bottom part of the cover there is a rectangular shaped seal made of foam rubber used to ensure watertightness and gastightness. In the standard installation, cover is tightened in the angles using four inbus screws, ensuring that seal fits the frame perfectly.
  • In the standard installation, frame is made of EPDM rubber. When additional waste water resistance is required, seal is made of NBR rubber.
  • Due to better contact with concrete, during installation frame has appropriate anchor wings on it.
  • Cover is made according to DIN EN 124:1994 standard, „Gully tops and manhole tops for vehicular and pedestrian areas"

 

02. LIGHT WATER TIGHT MANHOLE COVER

EKOguard COV 3

LAKI VODOTIJESNI POKLOPAC ZA OKNO
Basic measures
:
  • Light opening sewage cover standard dimensions:
    SQUERE COVER DIMENSIONS
    500 x 500
    630 x 630
    600 x 600
    730 x 730
    700 x 700
    830 x 830
    800 x 800
    930 x 930
Load:
  • These covers are appropriate only for the zone without any load, for shutting revision manholes in sewage systems or drinking water systems. Covers are made of profiled sheet, 3mm thick.
Application:
  • Constructed for installation on: manholes for waste or drinking water, ventilation chambers, pumping shafts and other facilities.
  • When there is a necessity for closing channel or some other kind of bigger opening, covers are installed in series, one next to another
Cover and frame design:
  • Cover is made of stainless steel sheets, due to additional stiffness, lifted on the diagonals
  • At the frame's edge, between the cover and frame, profiled seal is installed. Also, between frame and concrete base, there is a rectangular seal made of foam rubber. Both seals ensure watertightness and gastightness.
  • In the standard installation, frame is made of EPDM rubber. When additional waste water resistance is required, seal is made of NBR rubber.

LAKI VODOTIJESNI POKLOPAC ZA OKNO


03. HEAVY WATER TIGHT MANHOLE COVER

EKOguard COV 5

 

TEŠKI VODOTIJESNI POKLOPAC ZA OKNO


Basic measures:
  • Available dimensions:
    A - LIGHT OPENING LENGHT
    500 – 1000 mm
    B - LIGHT OPENING WIDTH
    500 – 1000 mm
  • Available cover load:
    Available cover load
    (According to DIN EN 124:1994
    Areas inaccessible to motor vehicles
    A15
    15 kN – 1,5t
     Footways, pedestrian areas
    B125
    125 kN – 12,5t
    Gully tips in kerbside channels
    C250
    250 kN – 25t
    Carrigeways of roads - heavy duty
    D400
    400 kN – 40t
Application:
  • Covers are installed in the areas with traffic load, exposed to load from vehicles or pedestrians. Depending on installation location, appropriate cover is installed.
  • When there is a necessity for closing longer or wider channels, covers are installed in series, one next to another
Cover and frame design:
  • Cover frame is installed into concrete, with the cover top in level with surrounding surface. On the frame's outer rim, there are anchor plates used to additionally ensure quality interaction between concrete and frame. This part is important because the entire load is transferred over the cover and frame to the concrete.
  • On the bottom side of the cover there is foam rubber seal ensuring water tight ness of cover to the frame. Cover is also equiped with a lock, with the optional special key.
  • In the standard installation, seal is made of EPDM rubber. When additional waste water resistance is required, seal is made of NBR rubber.
  • With covers with capacity over 125kN and more, due to additional cover weight, gas springs are installed on the bottom side of the cover in order to enable single handed opening.
  • Cover is made according to DIN EN 124:1994 standard, "Gully tops and manhole tops for vehicular and pedestrian areas"

 

04. PRESSURE COVERS

EKOguard COV 7

Tlačni poklopac
Basic measures
:
  • Available dimensions:
    AVAILABLE COVER DIMENSIONS
    LIGHT OPENING DIAMETER
    D (mm)
    FRAME OUTER DIAMETER
    D1 (mm)
    Ø600
    Ø840
    Ø700
    Ø940
    Ø800
    Ø1040
    Ø900
    Ø1140
    Ø1000
    Ø12
Application:
  • These covers are used for shutting revision concrete manholes under pressure (for example: in pressure sewage systems)
  • Construction for installation in: drinking and waste water manholes, pumping stations and other facility shafts
Cover and frame design:
  • Cover seal is square profile rubber seal; EMDP or NBR; 60 ShA, ensuring watertightness and gastightness in the cover-frame connection.
  • On the bottom side of the base round frame, there is a flat seal with rectangular profile, used to ensure sealing between round cover frame and concrete base.
Tlačni poklopac

 

 

Zaštita podataka